Josh Payne retweeted
🚨Latest #OpenAccess Article in@JICE_EP
Validation of an Automated Premature Ventricular Contraction Mapping Algorithm
🧐📖doi.org/10.1007/s10840-025-0…
by Yuji Ishida, Michael R. Gold, Joshua E. Payne, Adam R. Bainey, Michael E. Field, @BadertscherPat & @JRWinterfield
#EPeeps
Josh Payne retweeted
Grateful to @MUSC_EP fellows and former colleagues for the work to get this #PVC mapping paper out to @JICE_EP. Shifts in 3D space between sinus rhythm and PVCs influence accuracy of mapping points, a problem addressed by @JNJMedTech LAT-HYBRID module.
@DrGregMichaud
@BadertscherPat
link.springer.com/article/10…
Josh Payne retweeted
Peak frequency mapping with our #EnSiteX EP System can help locate PVC ablation targets by identifying high-frequency sites linked to successful suppression.
Explore the technique in #Europace: academic.oup.com/europace/ar…
Safety Info: bit.ly/4n7v5Av
#AbbottProud
Josh Payne retweeted
🚨New #FreeRead in @JICE_EP
Epicardial VT Ablation with a Pentaspline Catheter during Left Ventricular Assist Device Placement
🧐📖rdcu.be/eujIH
by @JPayne_EP, Marshall Bell, Luke Cunningham & Sean Halleran
#EPeeps
Josh Payne retweeted
The latest video in our partnership with @DGlaucomflecken summarizes the results of the VANISH2 trial, which compared catheter ablation versus antiarrhythmic drug therapy for ventricular tachycardia. View the full article for free: nej.md/DrG16
Josh Payne retweeted
For all #EPeeps
🧑🎓 In the next few weeks, I will be posting X threads on the 10 top-cited @hrs_journal articles of 2024. A lot of great science to choose from, so let’s dive right into the first of these (in no particular order!)
1⃣ Let's start with an excellent practical approach to VT ablation by my former @brigham co-fellow @jeffw and my former @mizzou fellow @jpayne
**‘A novel automated peak frequency annotation algorithm for identifying deceleration zones and ventricular tachycardia ablation sites’ Heart Rhythm, Volume 21, Issue 1, 27 – 33 heartrhythmjournal.com/artic…
Josh Payne retweeted
The second P' appears negative while the first P is positive. An alternative diagnosis is sinus, PVC with retrograde conduction, echo beat. All 3 are plausible.
Josh Payne retweeted
Excited to collaborate with @AbbottCardio and team up with this faculty to discuss current challenges and emerging opportunities to link mechanism with mapping and ablation strategies to #AblateVT
Will present @JPayne_EP work as part of discussion:
heartrhythmjournal.com/artic…
@MUSC_EP
@MUSC_Cardiology
@docAnneSquared
@dhakalbish
@rachelkaplanmd
@ChauVoMD
Flying to Denver as a faculty of a very intense VT course! And honour to join such a nice pannel! @DrRoderickTung Dr. Wendy Tzou @JRWinterfield @DrMatthewHyman @JenCheeMD @DanielAlyeshmer @hospitalclinic
Josh Payne retweeted
Outstanding paper from @jcdiaz1234 and @JorgeERomeroMD
LV Septal Pacing near the LBB area (but not capturing LBB) had similar outcomes to BiV pacing. LBB pacing still had superior outcomes over LV septal and BiV pacing. @DrRoderickTung @MihailChelu
jacc.org/doi/10.1016/j.jacep…
Josh Payne retweeted
Major Declines in Physician Reimbursement in Electrophysiology hmpgloballearningnetwork.com…
Josh Payne retweeted
Calling all friends of @MedicineForward. THIS IS BIG. New Jersey has a bill to be voted on Nov 20 to start to change the game on prior auth. If you care about fixing broken healthcare, this is your time do something. Together we can #FixPriorAuth. Let’s go!
Josh Payne retweeted
Proud to have assisted some great EPs on this work and thankful for their pursuit of new methods to help patients with VT.
High frequency in scar to identify decel Zones using #EnsiteX
Check out the video in the comments.
@JPayne_EP @JRWinterfield
heartrhythmjournal.com/artic… – at South Carolina, USA
Josh Payne retweeted
Congratulations to @leahjohnMD and many contributors including @RyanTedfordMD @JPayne_EP @Dr_Santangeli for development of CT substrate imaging based model for predicting HD decompensation during #AblateVT. sciencedirect.com/science/ar… @inheartmedical @ihu_liryc – at South Carolina, USA
Josh Payne retweeted
Looks like lead! But it isn’t! Equivalent radiation protection with barium sulfate, bismuth oxide impregnated fabric. Lighter washable why didn’t I know bout this?
Josh Payne retweeted
@ABIMFoundation please reply here so we all understand what these MOC fees get us. Paying the >$3,000 to pass the general and interventional cardiology recert exams isn’t enough for you. Please explain why. No answer assumes greed. We will all wait… – at Gainesville, GA
Josh Payne retweeted
Sarcoid VT w/ @JRWinterfield, widespread scar, and multiple DZs in RV and LV. Single pacemap helped us key in on area just under a LOB(adjacent to a DZ). Entrainment perfect and term in 4s. What to do next? Ablate all remaining targets or consolidate area and call it quits?
Josh Payne retweeted
Beautiful surgical dissection by @DrZeigler1 and @ct_musc with mapping in OR by @JPayne_EP @DanBLevinMD and @AbbottCardio mapper @AMatthews0 - non inducible at case end. – at Mount Pleasant, SC
Josh Payne retweeted
Great collaborative case with interventional friends @dhsteinberg and @mevansMD and great use of the Alpha Vac for vegetation aspiration during lead extraction! @DanBLevinMD @MUSC_EP @MUSCCardFellows @JRWinterfield @DrZeigler1 @laserlead – at South Carolina, USA
































