
EP Clinical Specialist #EnSite #PDXMapping @AbbottEP
Joined October 2021
- Tweets342
- Following69
- Followers236
- Likes351
Jordan Hemmen retweeted
#VoltPFA with #EnSiteEcho integration.
An efficient accurate electroanatomic workflow.
@Ashit_EPS
@EP_EmilyS
@AbbottCardio
Jordan Hemmen retweeted
Second-generation by design.
Efficient, tissue-directed irreversible electroporation.
Now with EnSite™ Echo integration.
@AbbottCardio
@Ashit_EPS
#Volt #PFA #ICE #PDXMapping
Jordan Hemmen retweeted
What actually "looks good" on ICE:
#ViewFlex Left Atrial imaging @EPS_PDX
Training @MRazminia
Sponsored @AbbottCardio
Complemented #EnSiteX PFA Visualization & Contact Index software.
A post PFA induced tachycardia, entrained at downstream electrogram, with long upstream capture (>75%, seen on splines) confirmed #Reentrant mechanism & circuit participation.
Despite multiple PFA applications, unable to achieve anterior block for mitral flutter. Epicardial voltage with peak frequency emphasis highlighted RF target. Lateral splits seen after first TactiFlex application.
#HDGrid
@AbbottCardio @EPS_PDX
Jordan Hemmen retweeted
A mappable VT meandering through WaDLs / Lines Of Block.
Intuitive S3 Protocol discontinuities, 98% Correlation Score, and VT activation maps, supported a thoughtful ablation strategy.
#EnSite
@AbbottCardio
Jordan Hemmen retweeted
The notorious papillary muscle PVC. Originating from lateral aspect of the pap, these bigeminal PVCs were eliminated during the first RF session with the help of the tried and true PDX method.
Link to publication:
pmc.ncbi.nlm.nih.gov/article…
Jordan Hemmen retweeted
Monday started with First-in-Human Use of “ViewFlex X SE” ICE Catheter with @AbbottCardio
I've always loved using the ViewFlex ICE for its exceptional image quality, but now with seamless ICE integration into Ensite X, this is a total game-changer that enhances precision like never before.
Some features that stood out to me
🔹 ICE Integration with Grid and FAM Mapping - Real-time visualization that aligns perfectly with 3D GridX and FAM maps. This precision ensures more efficient targeting of critical anatomy, improving procedural accuracy.
🔹 Smooth Transition to the Left Atrium
Despite its softer shaft, the ViewFlex X SE provided excellent maneuverability and control, allowing smooth navigation to the left atrium while maintaining consistent imaging quality.
🔹 Maintaining Outstanding Image Quality
For those of us who’ve always trusted the ViewFlex ICE platform for its superior imaging, this new catheter doesn’t disappoint—it adds seamless integration without compromising clarity.
#3DMapping #PrecisionMedicine #ViewFlexXSE #Innovation #EPWorkflow @StBernards #epeeps #ArrhythmiaResearchGroup
Jordan Hemmen retweeted
Premature His Bundle Complexes distinguished AVRT and AVNRT with 100% Specificity and Sensitivity irrespective of location.
A simple & intuitive maneuver.
PHC delivered 42 msec ahead of HIS, perturbed A1-A2 by 15 msec = AVNRT.
@PadanilamBenzy
@Ashit_EPS
@EP_EmilyS
@AbbottCardio
@CirculationEP
#EnSite
doi.org/10.1161/CIRCEP.119.0…
Jordan Hemmen retweeted
Prior PVI and PWI. Narrow channel of slow conduction on the roof identified by #HDGrid. Entrainment yields a return interval of 0 ms; the roof is in this atypical flutter’s circuit. #Entrainment #PMA @bmetzlerEP @madiwcEPdrop @EPS_PDX
Jordan Hemmen retweeted
An unstable VT.
Mappable with #StaMP.
Guided by S3 Protocol.
@JeffHsingMD
@EP_EmilyS
- StaMP @DrRoderickTung
- S3 Protocol @ivroca
- PDX Technique @B_Naz_MD
- #EnSite @AbbottCardio
Jordan Hemmen retweeted
Clinical PVC mapped to moderator band via continuous score mapping with a correlation of 96%. The PDX technique was employed to project points to endocavitary structures, enabling precise identification and visualization of the ablation target. #PMA
pmc.ncbi.nlm.nih.gov/article…
Jordan Hemmen retweeted
Hx PVI + PW, presenting with typical AFL.
CTI & re-isolation of LPV performed.
During left atrial post mapping, induced 230 msec tachycardia.
Inadvertently terminating during left atrial mapping, though incomplete, passively activated.
Unable to reinduce.
Right Atrial, S3 Protocol was performed.
@ivroca
@Ashit_EPS
@jordinarymaps
@AbbottCardio
#EPeeps
#PMA
#EnSite
jacc.org/doi/10.1016/j.jacep…
Jordan Hemmen retweeted
Increased ectopy during ablation at this AT’s site of earliest activation, demonstrating irritation of the tachycardia’s focus @JaylynnMariePDX @EP_EmilyS #PMA
Jordan Hemmen retweeted
S3 protocol, once again proved valuable in identifying ablation targets within this complex ischemic substrate.
Impressive decoupling of EGM's, otherwise missed with fixed S1 mapping.
#AblateVT
@ESC_Journals
@AbbottCardio
academic.oup.com/europace/ar…
Jordan Hemmen retweeted
2nd post: Terminated Mitral to second flutter. Can you see what it is on the left side of the screen? #PMA
Jordan Hemmen retweeted
An untouched atrium, presenting with concordantly positive p-waves.
A Reset ExtraStimulus Map helped limit ablation beyond PVI, despite multiple areas of deceleration and potential participating circuits.
#PMA
#Entrainment
@Ashit_EPS
@jordinarymaps
@AbbottCardio
Jordan Hemmen retweeted
The right lateral tricuspid annulus, a notoriously difficult ablation, despite alluring target.
sciencedirect.com/science/ar…
Tricuspid annular plane systolic excursion (TAPSE), one factor for stability.
sciencedirect.com/topics/nur…
#PMA
@DrEPCheng
@EP_EmilyS
@AbbottCardio
Jordan Hemmen retweeted
First of 3 posts on this case. Started case with Clockwise Mitral flutter despite posterior wall scar #PMA
Jordan Hemmen retweeted
Alternative form of entrainment with a sensed extrastimulus beat from a site of late activation. The paced wavefront travels orthodromically, captures atrial EGMs upstream, and resets the tach. The RA lateral wall is within the tach circuit. #PMA #REM
pubmed.ncbi.nlm.nih.gov/3351…
VT critical isthmus (left) correlated with deceleration zones localized with S3 protocol (right) @ivroca
xitter.cf/jaccjournals/status/18…
#AblateVT
@Ashit_EPS
@forkknifecab_EP
@AbbottCardio
The novel S3 whole-chamber protocol for assessing the ventricular functional substrate is feasible in 85% of patients, allows better identification of targets for ablation, and might improve VT ablation results. bit.ly/4c6k2kw
#JACCCEP #EPeeps #epAblation






















